Hoshizaki “A Superior Degree of Reliability” www.hoshizaki.com Models KMD-901MAH KMD-901MWH KMD-901MRH Modular Crescent Cuber Hoshizaki America, Inc
10II. Installation and Operating InstructionsA. Checks Before InstallationIMPORTANT1. Install in accordance with all applicable national, state, and l
11C. LocationCAUTION1. This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F to +100°F (+7°C to +
12E. Electrical ConnectionWARNING1. Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided wi
13F. Installation of Remote Condenser Unit1. Checks Before Installation1) Remove the shipping carton, tape, and packing material.2) Check that the ref
143. Setup1) Secure the legs to the remote condenser unit with eight M8×16 mm hexagon bolts and M8 nuts as shown in the illustration. See Fig. 5.2) Th
15Factory Line Set Installation1) Route the factory line set (1/2" OD discharge line and 3/8" OD liquid line) from the remote condenser unit
165. Electrical ConnectionWARNING1. Electrical connections must meet national, state, and local electrical code requirements. Failure to meet these co
17G. Water Supply and Drain ConnectionsSee Fig. 9CAUTIONTo prevent damage to equipment, do not operate the icemaker when the water supply is off, or i
18Fig. 9KMD-901MAHKMD-901MRHKMD-901MWHwith Storage BinIcemakerDrain Outlet 3/4" FPTIcemaker Water Supply Inlet1/2" FPTCondenser Water Supply
19H. Final Checklist 1) Is the icemaker level?2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F (+7°C to +38°C) and
2IMPORTANTOnly qualied service technicians should attempt to install, service, or maintain this icemaker. No installation, service, or maintenance sh
20I. StartupCAUTION1. All parts are factory-adjusted. Improper adjustments may result in failure.2. If the icemaker is turned off, wait for at least 3
21III. Cleaning and MaintenanceIMPORTANTEnsure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is d
221. Cleaning Procedure1)Dilute13.5.oz.(400ml)ofHoshizaki"ScaleAway"with2.5gal.(9.5l)ofwarmwater.2) Remove all ice from t
239) Fully open the cleaning valve on the left side wall of the machine compartment.10) Move the control switch on the control box to the "WASH&q
243) Pour the sanitizing solution into the water tank.4) Replace the insulation panel and the front panel in their correct positions.Note: Make sure t
253. Air Filters (air-cooled model only)Plastic mesh air lters remove dirt and dust from the air, and keep the condenser from getting clogged. As the
266) Blow the icemaker water supply line out using the compressed air or carbon dioxide supply.7) Close the icemaker water supply line drain valve.3.
27HOSHIZAKI AMERICA, INC.618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A1WD10B
3IMPORTANTThis manual should be read carefully before the icemaker is installed and operated. Only qualied service technicians should install, servic
4MOTOR-COMPRESSOR THERMALLY PROTECTED, NOT INTENDED FOR OUTDOOR USE!Hoshizaki America, Inc.Peachtree City, GAwww.hoshizaki.comICE MAKER WITHOUT STORAG
5MOTOR-COMPRESSOR THERMALLY PROTECTED, NOT INTENDED FOR OUTDOOR USE!Hoshizaki America, Inc.Peachtree City, GAwww.hoshizaki.comICE MAKER WITHOUT STORAG
63. KMD-901MRH (remote air-cooled)See the nameplate for electrical and refrigeration specications. This nameplate is located on the rear panel.Since
7B. Dimensions / Connections1. KMD-901MAHUnit: mm [inches]
82. KMD-901MWHUnit: mm [inches]
93. KMD-901MRHUnit: mm [inches]
Commenti su questo manuale